Control Module Quality Reliability Test In Data Acquisition In Simulation

  • Wandy Nata Adiguna Universitas Pembangunan Panca Budi
  • Adi Sastra P Tarigan Universitas Pembangunan Panca Budi
  • Solly Aryza Universitas Pembangunan Panca Budi
Keywords: Control System, Interface, LabVIEW

Abstract

This paper describes the main advantages of this DAS module which is that it can be manufactured at a very affordable price and provides good performance is commonly used in industrial control systems. Alternative data acquisition system (DAS) modules can use the LabVIEW interface in motor control systems. The DAS module is controlled by the ATmega64 AVR microcontroller which will communicate in both directions with LabVIEW using the serial communication method. Which is used to obtain 8-bit digital input, 8-bit digital output, 8 analog input channels, and also 2 analog output channels. Digital inputs can be used for 0-5V and 0-24V voltages. The digital output is made open collector with a "low" voltage of 0.276V. For analog input and analog output, this system has an average error of 14.47  in the input range of 1-5V; 72.34  for the 0-10V input range; 0.037 MA for 4-20mA input range, and 16.2  for the 0-10V output range. This system is not designed for use in applications that require real-time accuracy and fast accuracy

Downloads

Download data is not yet available.

References

Adityawarman, Dimas Zebua, O., & Hakim, L. (2011). Design and Build a Current Measuring Tool Using Atmega32 Microcontroller Based Current Transformer. Electricians, 8(2), 45–56.G. Smith, “Paper Title” (to be published).

Andi Aulia Rahman. (2019). DESIGN AND CONSTRUCTION OF AIR QUALITY MONITORING SYSTEM USING WEB-BASED WIRELESS SIGNAL NETWORK (WSN). 63.

Aryza, S., Irwanto, M., Khairunizam, W., Lubis, Z., Putri, M., Ramadhan, A., Hulu, FN, Wibowo, P., Novalianda, S., & Rahim, R. ( 2018). An effect sensitivity harmonics of rotor induction motors based on fuzzy logic. International Journal of Engineering and Technology(UAE), 7(2.13 Special Issue 13), 418–420. https://doi.org/10.14419/ijet.v7i2.13.16936.

Aryza, Solly. (2018). A NOVELTY OF QUALITY FERTILIZER DRYER BASED ON SOLAR CELL AND ANN.

Choudhuri, S. G., & Agrawal, S. K. (2015). Simulation of vector controlled induction motor drive in MatLab for various applications: a comparative study. Michael Faraday IET International Summit 2015, 93 (8 .)-93 (8 .). https://doi.org/10.1049/cp.2015.1689

Engineering, I. (2014). Speed Control of Three Phase Induction Motor Using Fuzzy Logic Controller by Space. 13650–13656.

Faroqi, Adam Hadisantoso, E. P., Halim, D. K., & WS, M. S. (2017). Design of Air Pollution Detector Using MQ-7 Gas Sensor With Wirelles HC-05 Technology. Journal of ISTEK, X(2), 33–47.

Indar Sugiarto, Thiang Thiang, & Timothy Joy Siswanto. (2008). Design and Implementation of Data Acquisition Module as an Alternative to LabVIEW DAQ Module. Journal of Electrical Engineering,8(1),30–37. http://puslit2.petra.ac.id/ejournal/index.php/elk/article/view/17353.

Nanang Kurniawan. (2018). ANALYSIS OF MULTI NODES MONITORING SYSTEM USING nRF24L01+ TRANSCEIVER IN REAL TIME. In Russian Journal of Economics (Vol. 48, Issue 2).

Published
2021-12-31
How to Cite
Adiguna, W. N., Adi Sastra P Tarigan, & Aryza, S. (2021). Control Module Quality Reliability Test In Data Acquisition In Simulation. INFOKUM, 10(1), 617-623. Retrieved from https://infor.seaninstitute.org/index.php/infokum/article/view/364

Most read articles by the same author(s)

1 2 3 > >>