An Analysis Performance Reliability Of Air Conditioner Comprecor Motors Based On Power Quality
Abstract
A Poor power quality, such as voltage fluctuations and harmonic interference, can affect compressor motor performance and life. So this research uses direct measurement and simulation methods to evaluate the influence of various power quality parameters on AC compressor motors. This research aims to analyze the performance reliability of compressor motors in air conditioner (AC) systems based on electrical power quality. and several tests show that harmonic interference and voltage variations significantly affect the efficiency and reliability of the compressor motor. Motors operating under poor power quality conditions exhibit increased operating temperatures, reduced efficiency, and shortened lifespan. The use of harmonic filters and voltage stabilizers has proven effective in improving power quality and, thereby, AC compressor motor performance. This research emphasizes the importance of maintaining power quality to ensure the reliability and efficiency of the compressor motor in the AC system. The implementation of power stabilizer and harmonic filter technology is recommended for industries that use compressor motors extensively, in order to optimize performance and reduce operational costs and made important contributions in the areas of power quality management and preventive maintenance for HVAC (Heating, Ventilation, and Air Conditioning) systems, with a particular focus on compressor motors as a key component in these systems.
Downloads
References
[2] BEE (Bureau of Energy Efficiency) India. 2002.
[3] Aryza, S., Wibowo, P., & Saputra, D. (2022, July). Rancang Bangun Alat Pengontrolan Proses Pemanasan Produksi Biodisel Dari Minyak Jelantah Berbasis Arduino Mega. In Prosiding Seminar Nasional Sosial, Humaniora, dan Teknologi (pp. 121-127).
[4] Aryza, S., Pratama, S., & Ikbal, M. (2022). An Enhance System Smart Toilet Based On Recycle Green Control. Infokum, 10(02), 1156-1163.
[5] Energy Performance Assesment of HVAC Systems. India. Ministry of Power. R.K.Puram, New Delhi-110066. 4Ch9. Halaman 115-121.
[6] Eugene Stamper, Richard L Koral (Editors). Handbook of Air Conditioning Heating and Ventilating (Third Edition). Industrial Press Inc., 200 Madison Ave. New York 10016. ISBN 0-8311-1124-0. Hal.30.
[7] Esparuling, Budiman Sudia, La Hasanuddin. 2018. Studi Eksperimen Pengaruh Kecepatan Putar Mesin Penggerak Kompresor Pada Sistem Kelistrikan Ac Mobil. Enthalpy- Soedjana Sapiie. 2005. Pengukuran dan Alat- Alat Ukur Listrik. Pradnya Paramitha:Jakarta.
[8] Furqan, M., Lubis, S. A., & Harahap, R. L. (2022). Automatic Plant Watering System Based on Air Temperature and Soil Humidity Using the Fuzzy Sugeno Method. Sinkron: jurnal dan penelitian teknik informatika, 6(4), 2576-2583.
[9] Ibrahim, M., Lubis, S. A., & Wibowo, P. (2021). Rancang Bangun Sistem Kendali Kelistrikan Cerdas Pada Rumah Tinggal Berbasis PLC. Kumpulan Karya Ilmiah Mahasiswa Fakultas sains dan Tekhnologi, 2(2), 35-35.
[10] Supratman Hara, dkk. 1996. Refrigerasi dan Pengkondisian Udara Edisi Kedua. Erlangga:Jakarta.
[11] Jurnal Ilmiah Mahasiswa Teknik Mesin. Vol. 3, No. 1, Maret 2018 e-ISSN: 25028944.Jian Zhao/Yangwei Yu. Brushless DC Motor Fundamentals. AN047 Rev. 1.0.
[12] Rahmaniar, R., Syahputra, M. R., Lesmana, D., & Junaidi, A. (2022). Sosialisasi Pemahaman Bahaya Tegangan Sentuh Dan Hubung Singkat Sistem Kelistrikan Bagi Masyarakat Desa Kota Pari. RESWARA: Jurnal Pengabdian Kepada Masyarakat, 3(2), 357-362