A Fast De Couple Method As Power Flow Optimization In Cooking Oil Processing Factory Based Matlab

  • Haris Gunawan Universitas Pembangunan Panca Budi, Gatot Subroto street, Medan, North Sumatera, Indonesia
Keywords: Power losses, Fast de couple, Matlab 7.0

Abstract

Power losses that occur in transmission lines result in various impacts that arise, including a decrease in voltage on the transmission line, low power factor that occurs. To reduce the occurrence of power losses that occur in transmission lines, capacitors are installed. In installing capacitors, attention must be paid to the channels that use them, the location of the capacitor and the size of the capacitor used. This is done so that the placement of the capacitor can be optimal in reducing the power losses that occur.This analysis is applied using the fast de-coupling method on a 20 kV power system.with applicationMatlab 7.0, after analysisknowntotal P loss – loss = 76,025 kW, and Q loss = 216,077 kVAR. After optimization by adding a capacitor to bus 2, it was found that the power losses were smaller, namely total P loss – loss = 46,438 kW and Q loss = 125,307 kVAR.

Downloads

Download data is not yet available.

References

[1] Meliandri Ed, Et Al 2012, Journal “Optimal Power Flow Analysis In Bali Electrical System” Electrical Technology Vol. 1 No 11.
[2] Muammar Zainuddin, Et Al., 2014 Journal “Optimization Of Photovoltaic Distributed Generations (Pvdg) Injection Using Genetic Algorithm Method” L Eeccis Vol. 8, No. 2.
[3] Ken Kevin Samosir, Et Al., 2014 "Comparison Of The Fast De Couple Method And The Gauss Siedel Method In The Solution Of The Power Flow Of The 20 Kv Distribution System Using Etap Power Station And Matlab" (Application At Pt.Pln Persero, Medan Branch),Singuda Ensikomm Vol. 7 No. 2
[4] Unggul Dzackiy Et Al., 2012, Journal “Optimization Of Capacitor Placement Using Fuzzy Logic And Genetic Algorithm In Electric Power Distribution System”, Department Of Electrical Engineering, Faculty Of Engineering, Diponegoro University.
[5] Heru Dibyo Laksono, 2010, Journal “Optimization Of Capacitor Placement In Electric Power System Using Genetic Algorithm” (Case Study Of Pt. Pln Sumbar-Riau System), Issn: 0854 – 8471, No.34 Vol.1 Year Xvii
[6] Efrita Arfah Z, Et Al. 2013, Journal “Optimal Power Flow (Opf) Of Java Bali 500 Kv Power Plant Using Particle Swarmoptimization (Pso) Template Algorithm,” National Seminar On Applied Science And Technology, Isbn: 978-602-98569-1-0, Surabaya.
[7] Cekmas Cekdin, , 2005, Book “Theory And Examples Of Questions Using The Matlab Programming Language”, Andi Offset Publisher, Yogyakarta.
[8] Cekmas Cekdin, 2013, Book “Electric Power Transmission”, Publisher Andi Offset, Yogyakarta.
[9] Hilal, Hamzah. 2006. “Electric Power System Analysis Ii.” Center For Teaching Material Developmentumb. Mercu Buana University.
[10 ]Hadi, Sadaat. 2002. “ Power System Analysis”.John Wiley And Sons, Inc. : New York.
[11] 2006 Check-In Check-Out,Book“"Electric Power System Example Questions And Solutions Using Matlab"Publisher Andi Offset,Yogyakarta
[12] Muhamad Rizki Fauzi Et Al., 2014 Journal “Slack Bus Arrangement In Optimizing Power Flow In The Case Of Ieee 30 Bus Using The Newton-Raphson Newton Raphson Method In Matlab 7.0 Application”
Electrichsan, Vol. 1, No. 1.
[13] Sulistiyono 2010, Journal“Comparison Of Gauss-Seidel Method, Newton Raphson Method And Fast Decoupled Method In Power Flow Solution” Diponegoro University, Semarang
Published
2024-09-11
How to Cite
Haris Gunawan. (2024). A Fast De Couple Method As Power Flow Optimization In Cooking Oil Processing Factory Based Matlab. Jurnal Scientia, 13(04), 1317-1329. Retrieved from https://infor.seaninstitute.org/index.php/pendidikan/article/view/2613