An Analysis Of Floor Plate Reinforcement Structure Calculation Plan On Irian Supermarket Building Road Of Setia Budi Medan

  • Yosua Hot Rejeki Tamba Universitas Harapan Medan, Medan, North Sumatera, Indonesia
  • Darlina Tanjung Universitas Harapan Medan, Medan, North Sumatera, Indonesia
Keywords: Floor Plate, Concrete, Reinforcement, SNI

Abstract

The increasing number of tall buildings being built in the modern era now. Making it increasingly important to calculate accurate and comprehensive structures in accordance with applicable regulations, especially the Indonesian National Standard (SNI) and of course the building to be built is safe from all potential structural failures and the most efficient reinforcement used. In the Irian Supermarket Building project, Setia Budi Medan, an analysis of the level of safety of the floor slab structure is required in accordance with SNI 2847-2019 and an analysis of the most efficient reinforcement that can be used in the floor slab structure of the Irian Supermarket Building, Setia Budi Medan. And the formulation of the problem discussed is the level of safety of the building structure and the most efficient reinforcement that can be used. The research method is carried out using the case study method where the collection of field data and additional data, data is processed in accordance with SNI 2847-2019 and for reinforcement efficiency is done by increasing the distance between the reinforcements. The result is the value of As needed: 652.4 mm2 < As used: 670.4 mm2 for flexural reinforcement (2Ø8-150) and As needed: 455.4 mm2 < As used: 502.4 mm2 for shear reinforcement (2Ø8-200) so that the reinforcement used is safe to use while the total deflection: 16.6 mm > allowable deflection: 6.68 mm and ϕVc: 58650 N/mm > Vu: 32823.07 N/mm so that the thickness of the plate used is 120 mm safe to use. However, reinforcement efficiency cannot be done because the value of As needed: 652.4 mm2 > As used: 455.4 mm2 for flexural reinforcement (2Ø8-200) and As needed: 455.4 mm2 > As used: 401.92 mm2 for shear reinforcement (2Ø8-250) so that reinforcement efficiency cannot be carried out.

Downloads

Download data is not yet available.

References

Andrianto, B. 2019. Reinforced Concrete Slab Design for Building Structures in High Earthquake Areas. Yogyakarta: Gadjah Mada University.
Arsoni, H. Ali. 2017. Reinforced Beams and Plates. Surakarta: Muhammadiyah Press.
National Standardization Agency. 2019. SNI - 2847 - 2019 Structural Concrete Requirements for Buildings and Explanations. Jakarta: National Standardization Agency.
National Standardization Agency. 2020. SNI - 1727 - 2020 Minimum Design Loads and Related Criteria for Buildings and Other Structures. Jakarta: National Standardization Agency.
Cahya, I. 2019. Reinforced Concrete. Malang: UNIBRA Faculty of Engineering.
Department of Public Works, 1983. Indonesian Loading Regulations for Building Structures (PPIUG 1983). Bandung: Department of Public Works.
Department of Public Works, 1987. Indonesian Loading Regulations for Buildings. Bandung: Department of Public Works.
Hudori, M., & Rama Fari Saputra, A. 2020. Experimental Design for Making Self-Compacting Concrete Using a Mixture of Coconut Fiber and Superplasticizer. Journal of Civil Engineering, 20(2).
Irawan, J., Ilhami, I., & Noor, M. 2016. Repair of Floor Plate Structure of Tanjung Market Building, Tabalong Regency. Poros Teknik Journal, 8(1), 35-41.
Mahfud. 2016. Analysis of the Ground Floor Plate of the Multipurpose Building of Balikpapan State Polytechnic. Integrated Technology Journal, 4(1), 48-52.
Mayanti, P. Sekar and Nurmaidah. 2021. Evaluation of Floor Plate Planning at the Saffiyatul Amaliyyah Education Foundation Building, Jalan Kemuning Medan. Journal of Civil Mechanics Construction Engineering, 4(1), 9-20.
Pratomo, R. Bayu and Mahfuz Hudori. 2021. Analysis of Floor Plate Structure Calculation in the Solnet Building Construction Project. Conescintech Journal, 1(1), 765-780.
Vis, WC and Gideon Kusuma. 1997. Basics of Reinforced Concrete Design Series I. Jakarta: Erlangga.
Wangsadinata, Wiratman et al. 1979. Indonesian Reinforced Concrete Regulations Series II. Jakarta: Directorate of Building Problem Investigation.
Published
2024-10-01
How to Cite
Yosua Hot Rejeki Tamba, & Darlina Tanjung. (2024). An Analysis Of Floor Plate Reinforcement Structure Calculation Plan On Irian Supermarket Building Road Of Setia Budi Medan. Jurnal Scientia, 13(04), 1418-1431. Retrieved from https://infor.seaninstitute.org/index.php/pendidikan/article/view/2626